C403, No. 8 Xiyuan 9th Road, Xihu District, Hangzhou City, Zhejiang Province market@idtdisplay.com
Call Us :+86-18969088997
Compare AUO 12.1 inch industrial LCD panels by resolution, brightness, viewing angle, interface, operating temperature, outline dimensions and lifecycle. IDT Display supports model selection, cross-reference evaluation and stable supply for HMI, medical, automation and transportation projects.
Send the current panel model, annual demand, required brightness, interface, temperature range and touch requirements. We can provide compatible LCD modules, custom touchscreen, optical bonding, cables and controller board support.
Confirm mechanical dimensions, active area, resolution, interface, connector pinout, timing, brightness and temperature range before sampling.
Yes. Provide the complete original model number and application requirements for an engineering cross-reference review.
Yes. Projected capacitive or resistive touch, custom cover glass, optical bonding, cables and LCD controller boards are available for qualified projects.
Compare AUO 12.1-inch LCD panels by resolution, brightness, viewing angle and backlight requirements. The models below share a diagonal size but differ in pixel format and electrical requirements. Confirm the full model suffix, timing, connector pinout, mechanical drawing and controller support before approving a replacement.
Source: AUO Display Plus General Display Product Roadmap, Q2 2026, pages 35–36 (May 6, 2026). All entries list LVDS. Most specify −30 to +85 °C. The G121EAN01.4 final specification lists −20 to +70 °C. The .4 and .401 rows use their respective final specifications. These are historical roadmap specifications, not a live inventory feed. MP means mass production in the roadmap snapshot; it does not guarantee current availability. Backlight lifetime is not a warranty and must be checked against datasheet conditions.
| Model | Resolution | Brightness (nits) | Viewing angle H/V (°) | Backlight life (h) | LVDS bit depth / notes | Historical roadmap status |
|---|---|---|---|---|---|---|
| G121SN01.403 | 800 × 600 | 500 | 160 / 140 | 50,000 | 6 / 6-bit + FRC | MP in Q2 2026 snapshot |
| G121STN02.0 | 800 × 600 | 500 | 160 / 140 | 50,000 | 6 / 6-bit + FRC | MP in Q2 2026 snapshot |
| G121STN02.1 | 800 × 600 | 1500 | 160 / 140 | 50,000 | 6 / 6-bit + FRC | MP in Q2 2026 snapshot |
| G121XN01.001 | 1024 × 768 | 500 | 160 / 140 | 50,000 | 6 / 6-bit + FRC | MP in Q2 2026 snapshot |
| G121XTN02.0 | 1024 × 768 | 1000 | 160 / 140 | 50,000 | 6 / 6-bit + FRC | Green MP label; Q3.25 date shown in future timeline area — confirm latest status |
| G121EAN01.0 | 1280 × 800 | 500 | 178 / 178 | 70,000 | 6-bit + Hi-FRC | MP in Q2 2026 snapshot |
| G121EAN01.1 | 1280 × 800 | 400 | 178 / 178 | 50,000 | 6-bit + FRC | MP in Q2 2026 snapshot |
| G121EAN01.2 | 1280 × 800 | 1000 | 178 / 178 | 50,000 | 6-bit + Hi-FRC | MP in Q2 2026 snapshot |
| G121EAN01.3 | 1280 × 800 | 1500 | 178 / 178 | 50,000 | 6-bit + Hi-FRC; without LED driver | MP in Q2 2026 snapshot |
| G121EAN01.4 | 1280 × 800 | 400 | 178 / 178 | 50,000 | 6-bit or 8-bit | Operating range −20 to +70 °C. See model specification. |
| G121EAN01.401 | 1280 × 800 | 300 | 178 / 178 | 50,000 | 30-pin LVDS | Operating range −30 to +85 °C. See model specification. |
G121STN02.1 and G121EAN01.3 are listed at 1500 nits but have different resolutions. They are not interchangeable on brightness alone. G121EAN01.3 is explicitly marked without an LED driver; confirm the required external drive, dimming, power and thermal design. High luminance alone does not establish sunlight readability for a complete display assembly.
Only after checking host timing, controller support, interface pinout and the mechanical drawing. The same 12.1-inch diagonal does not establish an electrical or mechanical match.
The roadmap does not confirm current stock or lead time. Provide the exact model, revision and quantity for a current quotation and documentation check.
Send the original model, datasheet, drawing, host/controller details, required brightness, operating conditions, touch requirements and expected demand. Validate samples in the intended equipment before production approval.